solarpanelsforcommercialbuildings Offices, retail, hotels and leisure Book a roof survey

Commercial building solar panels in Brecon

Commercial roofs in Brecon tend to be flat, membrane covered and cluttered with plant, which shapes the layout more than the size does. What decides a scheme is the roof covering, the parapet height and the plant layout, which is why the survey happens on the roof rather than from a satellite image.

828 kWh per kWp a year at this latitude, so a 210 kWp array models at about 174,000 kWh. Source: EU PVGIS v5.2, SARAH3, 10 degree pitch, 14 percent system loss.

Book a roof survey in Brecon
60 m 32 m N plant screen shade, kept clear stair core edge strip 1.5 m phase 1
Drawing Brecon commercial roof
Roof 60 x 32 m, 1,920 m²
Array 210 kWp, east-west
Yield 174,000 kWh/yr
Scale 1:400 / Rev A / Powys

Illustrative layout for a flat commercial roof of this size, with plant, shade and access kept clear. Your own figures come from the roof survey.

890
office properties on the rating list in Powys (VOA, March 2025)
1,410
retail properties, 30 of them large-format (VOA, March 2025)
0
named commercial rooftop schemes on the planning record nearby (REPD, Q1 2026)
Aerial view of an out-of-town retail park where some of the large unit roofs carry solar arrays and others are bare
Commercial stock of the kind we survey across Powys. Generated illustration, not a named site.

Commercial rooftop solar across Powys

Yield on a Brecon commercial roof

Modelled irradiation here is 1,057 kWh per square metre a year on a low-tilt array, which works out at 828 kWh for every kWp installed (EU PVGIS v5.2, SARAH3, 10 degree pitch, 14 percent system loss). That is about 7 percent below the mean across the towns we cover, so the case here rests more on daytime consumption than on raw generation.

How many commercial buildings Powys has

On the Valuation Office Agency's count, Powys holds 1,410 retail and 890 office properties on the rating list. By office stock the district sits below the median of the 318 districts in England and Wales; by retail stock it sits above the median of the 318 districts in England and Wales.

The big roofs are in the 30 large-format retail units, superstores and retail warehouses in the district, about 63,000 square metres of floorspace under largely single storey roofs.

The same list carries 410 hotel, leisure and assembly properties in the district. Leisure centres and hotels run seven days a week, which puts weekend generation to use that an office would export.

Source: Valuation Office Agency, Non-domestic rating: business floorspace, 31 March 2025 (published December 2025), counts and floorspace by special category code and local authority district, England and Wales.

FIG. 1 What a Brecon roof makes, month by month

What a Brecon roof makes, month by month

Modelled output per kWp installed, for a shallow-pitched south-facing array. Source: EU PVGIS v5.2.

0255075100Jan: 20 kWh per kWpJanFeb: 34 kWh per kWpFebMar: 69 kWh per kWpMarApr: 100 kWh per kWpAprMay: 115 kWh per kWpMayJun: 116 kWh per kWpJun116 kWh Jul: 114 kWh per kWpJulAug: 97 kWh per kWpAugSep: 76 kWh per kWpSepOct: 44 kWh per kWpOctNov: 26 kWh per kWpNovDec: 17 kWh per kWpDec

Jun produces 6.8 times what Dec does on the same roof. A 210 kWp array here models at about 174,000 kWh across the year, but it arrives unevenly, which is why we size against your summer daytime load and then look at whether storage is worth adding for the shoulder months.

Monthly figures as a table
MonthkWh per kWp210 kWp array
Jan204,200
Feb347,140
Mar6914,490
Apr10021,000
May11524,150
Jun11624,360
Jul11423,940
Aug9720,370
Sep7615,960
Oct449,240
Nov265,460
Dec173,570
Source: EU PVGIS v5.2
FIG. 2 Brecon against the rest of Powys
  • Hay on Wye838
  • Welshpool831
  • Builth Wells830
  • Brecon828
  • Llandrindod Wells825
  • Newtown820

Brecon ranks 4 of 6 towns we cover in Powys on modelled yield, against a national mean of 886 kWh per kWp. The county runs from 820 to 838, a spread of 18 kWh per kWp. Within Powys that difference is small enough to ignore: where the building sits is not what decides this scheme, your consumption pattern is.

Bars are zero based, so length is proportional to the figure. Where a county is flat, that is the finding: location is not the lever, consumption is. Source: EU PVGIS v5.2, modelled per town

Grid connection through National Grid Electricity Distribution

National Grid Electricity Distribution is the network operator here, and their answer on export capacity shapes the design. Any commercial array above 3.68 kW per phase connects under G99 rather than G98, and the application fixes what you are allowed to push back onto the network. If the local network is tight, limiting export rarely breaks the case here: most of the generation is consumed on site while the building is working.

Across Powys the planning database records 18 solar schemes totalling 39 MW, of which 1 are operational (REPD Q1 2026).

Book the survey

Send us the postcode

Tell us where the building is, roughly how big the roof is, and whether you own it or lease it. We come back with what it can carry, what it would generate against your consumption, and the three ways to pay for it.

Lenzie Consulting Ltd arranges the survey and passes your details to our MCS-certified installation partner so they can quote.

We pass your details to our MCS-certified installation partner so they can quote. Read the privacy notice.

Questions about solar in Brecon

What would a 210 kWp array produce in Brecon?
Yes. At 828 kWh per kWp a year, a 210 kWp array on a Brecon roof models at around 174,000 kWh. What changes the answer is how much of that the building uses during opening hours rather than exports. Source: EU PVGIS v5.2, SARAH3, 10 degree pitch, 14 percent system loss.
Do we need planning permission for solar on a commercial building in Powys?
Usually not a full application. In England, panels on the roof of a non-domestic building are permitted development under Class J of Part 14 of the General Permitted Development Order, with no capacity cap since December 2023. Above 50 kW, which covers most commercial arrays, you must first apply to Powys for a determination on prior approval of the design and appearance, in particular glare on neighbouring land. On a flat roof panels may stand no more than 1 metre above the roof and must sit at least 1 metre from its edge, and listed buildings and scheduled monuments are excluded. See our planning permission guide for the detail.
Does solar help a Brecon landlord meet MEES?
It can. A non-domestic EPC is an asset rating, and on-site generation counts in the calculation, so an array usually lifts the score. Let property in England and Wales must be EPC E or better today. The government's interim response of 18 June 2026 proposes EPC B, where cost effective, from 2031 for let buildings over 1,000 m², and drops the EPC C step once planned for 2027. How far solar moves a particular building depends on its fabric and services, which is why the EPC assessor models it before anything is fitted.
Which network operator handles the connection in Brecon?
Capacity varies street by street and only National Grid Electricity Distribution can answer it for your connection. We ask early, because an export-limited offer changes the design rather than ending the scheme, and most commercial buildings use most of what they generate anyway.

Nearby

All Powys locations